Forest Service has published a combined synopsis/solicitation in the United States for: Research Triangle Park Forestry Sciences Laboratory HVAC Repair. Responses are due by 1 Dec 2026, 22:00 UTC (9 days left).
The Forest Service seeks HVAC repair for the Research Triangle Park Forestry Sciences Laboratory. Work covers a Mitsubishi VRF system (ACCU-1/VRV 2-7) serving the Forest Science and Assessment Center that is not holding set points and may have a refrigerant leak, plus redundant fan coil units at the Forestry Science Laboratory. This is a total small business set-aside under NAICS 238220.
This summary was written by AI from the official notice text. It can miss or misread details. The official notice is the authority.
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested and a separate written solicitation will not be issued. Solicitation number 1240B27Q0025 is issued as a Request for Quotation (RFQ) for Research Triangle Park Forestry Sciences Laboratory HVAC Repair This acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220 The small business size standard is $19 M This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency. The primary HVAC system (ACCU-1/VRV 2-7) for the Forest Science and Assessment Center (FSAC) is a Mitsubishi VRF system (BHM06227, Model PURY-P120TLMU-A, Serial 79W00897, 10 tons, R-410A) with 6 interior units. The system does not maintain condition set points and an initial evaluation during a preventative maintenance service call diagnosed with a potentially significant refrigerant leak. The Forestry Science Laboratory (FSL) building's Fan Coil Units (FCUs) are redundant in the current HVAC system. The outside air vents are no longer needed and are introducing unconditioned air into the building. During cold weather, this can lead to the coils potentially freezing and have led to the freeze-stats tripping, resulting in nuisance shutdowns.
Text from the official notice on SAM.gov Contract Opportunities (US). Long notices are shortened here. Read the complete notice at the source.
The United States federal government is the largest single buyer in the world. Contract opportunities expected to exceed $25,000 are published on SAM.gov as presolicitations, sources sought notices, solicitations and combined synopsis/solicitations.
All tenders in the United StatesGuide: How to bid on US federal contracts through SAM.gov
Keep looking
United StatesForest ServiceFacilities
United StatesForest ServiceFacilities
United StatesDefense Logistics AgencyConstruction
United StatesDepartmental OfficesConstruction
United StatesVeterans Affairs, Department ofConstruction
United StatesDepartment of the ArmyConstruction